What's New in Imprivata OneSign 23.2
Imprivata OneSign® 23.2 contains the following new features and technology updates.
NOTE:
New Features
Self-Service Virtual Smartcard Renewal
Users can now renew their own virtual smartcards using the existing NHS Care Identity Service site without having to contact a NHS Registration Authority user.
When a virtual smartcard is expiring, users are notified by an Imprivata popup warning, which appears at workstation login, showing the remaining effective days. In order to use the self-service feature, users must renew their smartcards before they expire. After expiration, users must go to the NHS Registration Authority.
Enterprise Migrations to G4 on Azure
OneSign 23.2 adds support for the following enterprise migrations:
-
G3 (third generation) on premises to G4 (fourth generation) on Azure
-
G3 on Azure to G4 on Azure
-
G4 on premises to G4 on Azure
-
Hybrid G3 to hybrid G4. A hybrid G3 enterprise has some G3 appliances on premises and some on Azure, and usually supports a disaster recovery configuration. A hybrid G3 enterprise can be migrated to a hybrid G4 enterprise with G4 appliances on premises and on Azure.
For the procedure for all migrations to a G4 enterprise, see
"Migrating to a G4 Enterprise" in the Upgrade Portal. For migrations to G4 on
Azure and for migrations of hybrid enterprises to G4, help topic
G4 Service Appliances and Larger G4 Appliances and Enterprises on Azure
OneSign 23.2 adds support for G4 service appliances on Azure and removes the previous limit of two total (database) appliances for a G4 enterprise on Azure. The largest standard G4 deployment has six total appliances in an Azure enterprise: two database appliances and four service appliances. Larger enterprises on Azure are supported, but may yield only marginal performance improvements. Larger capacity appliances are also now supported on Azure. For more information and guidance, see sections "G4 Appliance Basic Specifications on Azure" and "Number of G4 Appliances to Deploy on Azure" in help topic
You establish a G4 enterprise on Azure using a separate private product in the Azure Marketplace. (The G3 private product in the Azure Marketplace remains available.)
Both G4 and G3 products are moved in the Azure Marketplace from their previous location in "Private offers" to a new location in a "Private product" category.
Imprivata recommends that you deploy G4 appliances on Azure rather than G3 appliances, if possible. You cannot have G4 and G3 appliances on the same enterprise, so if needed, consider migrating your enterprise to G4.
Imprivata Single Sign-On Test Agent Supported on Chrome and Edge Chromium
The Imprivata single sign-on test agent is now supported on Google Chrome and Edge Chromium browsers.
OneSign and Confirm ID 7.11 and Later Releases Run Only on G4 Appliances
OneSign 7.11, Confirm ID 7.11, and later releases of those products run only on G4 (fourth generation) appliances in a G4 enterprise. If you’re running G3 (third generation) appliances in a G3 enterprise, or G2 (second generation) appliances in a G2 enterprise, and you want to upgrade to 7.11 or later, you must instead migrate to a G4 enterprise. You can install 7.11 or later as part of the migration process. For procedures to migrate from a G3 or G2 enterprise to a G4 enterprise, see "Migrating to a G4 Enterprise" in the Upgrade Portal.
Note that there are significant differences between G3 (or G2) and G4 appliances and sites. For information on G4 appliances, see
Rollback from a G4 enterprise to a G3 or G2 enterprise is not supported.
Technology Updates
FIDO Security Key Authentication
Fix for FIDO security key authentication on IGEL devices, version 11.09 and later.
Qualifications and Certifications
Microsoft 2020 LDAP Channel Binding and LDAP Signing Updates
While Microsoft has not announced a release date for their planned update to LDAP channel binding and LDAP signing requirements, it is recommended that Imprivata administrators verify that their Imprivata directory (domain) connections are configured for SSL. When the update is applied, any directory connection that is not configured for SSL may fail.
To verify the connection settings, go to the Directories page (Users menu > Directories) and open the required domain. Verify that Use TLS for secure communication is selected.
TLS Support
As part of Imprivata's continuing effort to increase our security posture, beginning with the 7.4 release, Imprivata disables the use of older TLS versions 1.0 and 1.1 for all G3 appliance communications.
For more information on TLS usage, see the "About TLS Communication" topic in the Imprivata Online Help.
Imprivata OneSign API Access
As part of Imprivata's continuing effort to increase our security posture, there are two modes of API access through the Imprivata OneSign ProveID Web API and ProveID Embedded:
-
Full
-
Restricted
In restricted mode, access to Password
and UserAppCreds
resources are disabled. A ResourceRequest
that includes an attribute id of Password
or UserAppCreds
returns a response with a message stating that access is restricted and status code 403
.
The settings to manage API access are on the API access page in the Imprivata Admin Console.
Imprivata Google Chrome Extension
The Imprivata agent continues to install the Chrome extension for SSO, but no longer enables it.
If you plan on installing Imprivata agents on new endpoints or upgrading existing Imprivata agents, you must enable/allow the extension using a Microsoft Active Directory GPO. Per the Chrome Safe Browsing Policy, a GPO is the only supported way to enable extensions silently.
NOTE: For complete details on enabling the Chrome extension, see "Support for Applications that Run in Google Chrome" in Imprivata OneSign help.
Support for ForceAuthN Attribute in OneSign WebSSO Integrations
ForceAuthN would typically be used when designing a SAML-enabled app to integrate with Imprivata OneSign WebSSO. Use the ForceAuthN attribute when a clinician must authenticate during a clinical workflow, while preserving their browser login.
Upgrade Considerations
Imprivata Platform Update - G4 Appliances
An upgrade to 23.2 requires that you install the Imprivata platform update (virtual-applianceG4-IMPRIVATA-2023-2-1.ipm) before upgrading the G4 appliance.
The platform update provides infrastructure, communication, and security improvements which must be in place before you upgrade.
Take note of the following considerations:
-
This platform update is supported on Imprivata OneSign 7.10 and later as part of the upgrade process or as a standalone update. If desired, you can install and distribute this platform update to your appliances without having to upgrade.
Use one of the following methods for uploading:
-
Upload the platform update files from a file server connected to the appliance. This is the preferred method for updating the appliances.
-
If you cannot use a file server, and need to upload the IPM from your local computer, using the Imprivata Appliance Console > Packages tab.
-
The upgrade from 7.8 or 7.9 to 23.2 requires that you must first upload the provided increasePHPmaxPOST-2022-3-1.ipm. This small platform update temporarily increases the maximum PHP file upload size, allowing you to then upload the virtual-applianceG4-IMPRIVATA-2023-2-1.ipm file.
-
The upgrade from 7.10 through 7.12 to 23.2 does not require the increasePHPmaxPOST-2022-3-1.ipm be uploaded first. You can simply upload the virtual-applianceG4-IMPRIVATA-2023-2-1.ipm platform update file
-
For more information about upgrading to 23.2, see the Imprivata Upgrade Help.
Considerations
The following sections describe changes in behavior in
Database Replication Status Icon and Text are Improved for G4 Service Appliances
An icon used to show database replication status in the Status box on the Imprivata home page is improved. For G4 service appliances, that icon is now a gray circle with a white interior. The icon indicates that a G4 service appliance does not have a database and therefore database replication status is not applicable to that appliance. In contrast, the icon of a green circle containing a white check mark still indicates that database replication is occurring normally for a G4 database appliance.
On the Sites page of the Imprivata Admin Console, the former Status column is now relabeled as database Replication Status to improve clarity. For a site having only a G4 service appliance, the database replication status value is now displayed as "Not applicable".
ImprivataAgent Refresh Interval – Recalculation of Minimum Allowed Value is Improved
The periodic recalculation of the minimum allowed value for the Imprivata agent refresh interval was improved to prevent the system from calculating and setting excessively large minimum allowed refresh interval values. Large minimum values can degrade system performance for end users.
Related configuration setting Refresh interval when agents check server for updates in this site appears in the Imprivata Admin Console, on the Settings page (Gear icon > Settings), in section System Settings. This setting shows the current Imprivata agent refresh interval and allowed range of values.
Over time, if the minimum allowed refresh interval increases to become greater than the current refresh interval, then the current refresh interval is increased automatically to match that new minimum value. An email is sent to the Imprivata system administrator to notify them of this change, and to tell them that this change is normal behavior in response to a recent increase in the number of concurrent sessions serviced.
However, conversely, if over time the minimum allowed refresh interval decreases, the current refresh interval is not changed automatically and the Imprivata administrator is not notified by email. In this situation, if desired, the administrator can manually decrease the current refresh interval to match the new minimum value.
For more information, see “Setting the Imprivata Agent Refresh Interval” in
G4 Appliances Ship with Four CPUs by Default in OneSign 7.11 and Later Releases
For OneSign 7.11 and later releases, G4 (fourth generation) appliances ship with four CPUs by default. When deploying new G4 service appliances on 7.11 or later, manually remove two CPUs. For related information, see "Appliance System Requirements and Guidance" in the Imprivata online help system.
Previously, for OneSign 7.8 through 7.10, G4 appliances shipped with two CPUs by default. For those earlier releases, when deploying new G4 database appliances, you had to manually add two CPUs to meet the requirements.
These defaults and requirements do not apply to G4 appliances on Azure. For information on G4 appliances on Azure, see topic “Deploy a G4 Appliance on Azure” in the Imprivata online help system.
New Appliances on Non-DHCP Networks Get Prepopulated Host and Domain Names
When you set up a new G3 or G4 appliance on a network that does not use DHCP, then in the Appliance Setup Wizard process, under System Information, the Host Name and Domain Name fields get prepopulated with values localhost and localdomain. Previously, in
Secure Walk Away – Imprivata ID Sensitivity Control May Need Adjustment for Nordic BLE Receiver
Imprivata Secure Walk Away added support for a Nordic Bluetooth Low Energy (BLE) receiver in OneSign and Confirm ID 7.11. The Bluetooth receiver sensitivity may vary for different mobile devices. If your users report that their workstations lock because Secure Walk Away does not detect their mobile devices, adjust the Secure Walk Away – Imprivata ID Sensitivity slider control in the computer policy assigned to those workstations. For more information, see topic